Saltar navegación principal
Normas DIN – AENOR
DIN EN ISO 11140-4:2005-12

DIN EN ISO 11140-4:2005-12

Sterilization of health care products - Chemical indicators - Part 4: Class 2 indicators as an alternative to Bowie and Dick test for detection of steam penetration (ISO/DIS 11140-4:2005); German version prEN ISO 11140-4:2005

Stérilisation des produits de santé - Indicateurs chimiques - Partie 4: Indicateurs de classe 2 comme alternative à l'essai de Bowie et Dick pour la détection de la pénétration de la vapeur (ISO/DIS 11140-4:2005); Version allemande prEN ISO 11140:2005

Sterilisation von Produkten für die Gesundheitsvorsorge - Chemische Indikatoren - Teil 4: Indikatoren der Klasse 2, die alternativ zum Bowie-Dick-Test für den Nachweis der Dampfdurchdringung verwendet werden (ISO/DIS 11140-4:2005); Deutsche Fassung prEN ISO 11140-4:2005

Fecha Anulación:
2017-07 /Withdrawn
Equivalencias internacionales:

ISO/DIS 11140-4 (2005-10)

prEN ISO 11140-4 (2005-10)

Relación con otras normas DIN:

Reemplazada por: DIN EN ISO 11140-4:2007-07

Resumen:
This European Standard specifies the performance requirements for a Class B indicator to be used as an alternative to the Bowie and Dick test for steam sterilizers for wrapped goods (instruments etc. and porous loads). An indicator complying with this European Standard incorporates a specified material which is used as a test load. This test load may, or may not, be reusable.
Keywords:
Aeration, Ageing (materials), Air, Biological hazards, Bodies, Bowie and Dick test, Calibration, Checking equipment, Chemical indicators, Classification systems, Conditions, Control, Control charts, Cycle, Defects, Definitions, Density, Determinations, Distance, Equipment, Geometry, Health protection, Heat, Indications, Indicators, Information, Leakage, Lighting systems, Limits (mathematics), Low pressure, Marking, Measurement, Measuring instruments, Medical devices, Medical products, Medical sciences, Medical technology, Methods, Non-biological, Optics, Packages, Penetrations, Performance, Personal health, Process, Product information, Quality assurance, References, Reflection, Sensitivity, Sensors, Sequence of operations, Signals, Specification, Specification (approval), Standards, Statistics, Steam sterilization, Steam sterilizers, Sterilization (hygiene), Sterilizers, Supply, Surveillance (approval), Systems, Test cycle, Testing, Testing conditions, Thermal hazards, Tracer methods, Use, Vapours, Verification, Wavelengths
99,72
Idioma Formato

Formato digital

Nota: Precios sin IVA ni gastos de envío

Añadir a la cesta