Saltar navegación principal
Normas DIN – AENOR
DIN 4017:2006-03

DIN 4017:2006-03

Soil - Calculation of design bearing capacity of soil beneath shallow foundations

Sol - Calcul de la charge de rupture du sol sous les fondations superficielles

Baugrund - Berechnung des Grundbruchwiderstands von Flachgründungen

Fecha:
2016-03 /Active
Relación con otras normas DIN:

Reemplaza a: DIN 4017:2001-06

Reemplaza a: DIN 4017-1:1979-08

Reemplaza a: DIN V 4017-100:1996-04

Reemplaza a: DIN 4017-2:1979-08

Resumen:
This standard applies to the calculation of design bearing capacity of soil beneath shallow foundations based on strata profiles and characteristics soil values according to DIN 4020. It deals with bases for calculation and calculation procedures which are used to determine the design bearing capacity in the surface of shallow foundations. The calculation procedures are based on the assumption that the shear parameters of every stratum to be considered are approximately unidirectional.
Keywords:
Angle of friction, Bearing pressure, Change of strata, Coefficient of safety, Construction, Definitions, Foundation engineering, Foundations, Load capacity, Loading, Mathematical calculations, Shallow foundations, Shape factors, Shear coefficient, Shear failures, Shear strength, Sliding surfaces, Soil mechanics, Soles, Strip foundations, Subfaces, Subsoil
64,67
Idioma Formato

Formato digital

Nota: Precios sin IVA ni gastos de envío

Añadir a la cesta