DIN EN 54-11:2001-10

DIN EN 54-11:2001-10

Fire detection and fire alarm systems - Part 11: Manual call points; German version EN 54-11:2001 / Note: DIN 14652 (1979-05), DIN 14654 (1979-05) and DIN 14655 (1979-05) remain valid alongside this standard until 2003-06-01.*To be replaced by DIN EN 54-11 (2013-04), DIN EN 54-11 (2015-09).*To be amended by DIN EN 54-11/A1 (2005-06).

Systèmes de détection automatique d'incendie - Partie 11: Déclencheurs manuels d'alarme; Version allemande EN 54-11:2001 / Attention: DIN 14652 (1979-05), DIN 14654 (1979-05) et DIN 14655 (1979-05) restent valable avec la présente norme jusqu'à 2003-06-01.*À remplacer par DIN EN 54-11 (2013-04), DIN EN 54-11 (2015-09).*Amendement prévu par DIN EN 54-11/A1 (2005-06).

Brandmeldeanlagen - Teil 11: Handfeuermelder; Deutsche Fassung EN 54-11:2001 / Achtung: Daneben gelten DIN 14652 (1979-05), DIN 14654 (1979-05) und DIN 14655 (1979-05) noch bis 2003-06-01.*Vorgesehener Ersatz durch DIN EN 54-11 (2013-04), DIN EN 54-11 (2015-09).*Vorgesehene Änderung durch DIN EN 54-11/A1 (2005-06).

Fecha:
2011-10 /Active
Equivalencias internacionales:

EN 54-11 (2001-05)

SN EN 54-11 (2001-07)

TS EN 54-11 (2004-04-22)

Relación con otras normas DIN:

Reemplaza a: DIN EN 54-11:1991-09

Reemplaza a: DIN 14655:1979-05

Reemplaza a: DIN 14654:1979-05

Reemplaza a: DIN 14652:1979-05

Modificada por: DIN EN 54-11/A1:2006-03

Resumen:
The document specifies the requirements and methods of test for manual call points in fire detection and fire alarm systems in and around buildings. It takes into account indoor and outdoor conditions, the appearance and operation of the manual call points for type A "direct operation" and type B "indirect operation" and covers those which are simple mechanical switches, those which are fitted with simple electronic components (e.g. resistors, diodes) and those which contain active electronic components and which work with the control panels for signalling and identifying, for example, an address or location. It does not cover manual call points for special applications, for example manual call points that are intrinsically safe or for use in hazardous conditions.
Keywords:
CE marking, Definitions, Fire alarm point, Fire alarms, Fire extinguishing devices, Flame detectors, Flames, Manual call points, Marking, Specification (approval), Test programs, Testing
83,93
Idioma Formato

Formato digital

Nota: Precios sin IVA ni gastos de envío

Añadir a la cesta