DIN EN ISO 16890-2:2020-09

DIN EN ISO 16890-2:2020-09

Air filters for general ventilation - Part 2: Measurement of fractional efficiency and air flow resistance (ISO/DIS 16890-2:2020); German and English version prEN ISO 16890-2:2020 / Note: Date of issue 2020-07-31*Intended as replacement for DIN EN ISO 16890-2 (2017-08).

Filtres à air de ventilation générale - Partie 2: Mesurage de l'efficacité spectrale et de la résistance à l'écoulement de l'air (ISO/DIS 16890-2:2020): Version allemande et anglaise prEN ISO 16890-2:2020) / Attention: Date de parution 2020-07-31*Prévu pour remplacer DIN EN ISO 16890-2 (2017-08).

Luftfilter für die allgemeine Raumlufttechnik - Teil 2: Ermittlung des Fraktionsabscheidegrades und des Durchflusswiderstandes (ISO/DIS 16890-2:2020); Deutsche und Englische Fassung prEN ISO 16890-2:2020 / Achtung: Erscheinungsdatum 2020-07-31*Vorgesehen als Ersatz für DIN EN ISO 16890-2 (2017-08).

Fecha:
2020-09 /Active
Equivalencias internacionales:

ISO/DIS 16890-2 (2020-06)

prEN ISO 16890-2 (2020-06)

Resumen:
EN ISO 16890-2 specifies the aerosol production, the test equipment and the test methods used for measuring fractional efficiency and air flow resistance of air filter for general ventilation. It is intended for use in conjunction with EN ISO 16890-1, EN ISO 16890-3 and EN ISO 16890-4. The test method described in this part of ISO 16890 is applicable for air flow rates between 0,25 m3/s (900 m3/h) and 1,5 m3/s (5400 m3/h), referring to a test rig with a nominal face area of 610 mm x 610 mm. EN ISO 16890 (all parts) refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested per the proce-dures defined within EN ISO 16890 (all parts). Air filter elements outside of this aerosol fraction are evaluated by other applicable test methods, (see ISO 29463 all parts). Filter elements used in portable room-air cleaners are excluded from the scope. The performance results obtained in accordance with ISO 16890 (all parts) cannot by themselves be quantitatively applied to predict performance in service with regard to efficiency and lifetime.
Keywords:
Aerosols, Air cleaning equipment, Air filters, Air resistance, Air-conditioning systems, Airflow resistance, Classification, Definitions, Efficiency, Electrostatic discharges, Electrostatics, Filter class, Filters, Flow measurements, Flows, Marking, Measuring techniques, Mechanical engineering, Particle filters, Particles, Separation efficiency, Specification (approval), Testing, Testing dust, Ventilation
148,41
Idioma Formato

Formato digital

Nota: Precios sin IVA ni gastos de envío