Saltar navegación principal
Normas DIN – AENOR
DIN EN 13565-2:2020-03

DIN EN 13565-2:2020-03

Fixed firefighting systems - Foam systems - Part 2: Design, construction and maintenance; German version EN 13565-2:2018+AC:2019

Installations fixes de lutte contre l'incendie - Systèmes à émulseurs - Partie 2: Calcul, installation et maintenance; Version allemande EN 13565-2:2018+AC:2019

Ortsfeste Brandbekämpfungsanlagen - Schaumlöschanlagen - Teil 2: Planung, Einbau und Wartung; Deutsche Fassung EN 13565-2:2018+AC:2019

Fecha:
2020-03 /Active
Equivalencias internacionales:

EN 13565-2+AC (2019-04)

Resumen:
This European Standard (DIN EN 13565-2) specifies the requirements and describes the methods for design, installation, testing and maintenance of low, medium, and high expansion foam fire extinguishing systems. Foam systems may be used to suppress the release of toxic vapours but this application is outside the scope of this document. This document provides guidance for the design of various foam systems available to persons with knowledge and experience in determining the selection of foam fire extinguishing systems which will be effective in protecting specific hazard configurations. For the application of this standard, a risk assessment by a qualified and experienced person should be performed for both new and existing systems, however the risk assessment is outside the scope of this document. This document does not cover a risk analysis carried out by a competent person. Nothing in this document is intended to restrict new technologies or alternative arrangements, provided that the level of foam system performance prescribed in this standard is not lowered, and supported by documented evidence/test reports. All foam systems are generally unsuitable for the following: - chemicals, such as cellulose nitrate, that release sufficient oxygen or other oxidizing agents which can sustain combustion; - energized unenclosed electrical equipment; - metals such as sodium, potassium and sodium-potassium alloys which are reactive to water; - hazardous, water-reactive materials such as triethyl-aluminium and phosphorous pentoxide; - combustible metals such as aluminium and magnesium.
Keywords:
Checks, Commissioning, Consumption, Definitions, Diameter, Examination (quality assurance), Extinguishing agents, Extinguishing centre, Extinguishing equipment, Fire brigade, Fire extinguishers, Fire extinguishing foam systems, Fire safety, Firefighting, Firefighting equipment, Fixed roof tanks, Floating roof, Foam producers, Foams, Maintenance, Mounting, Pipework systems, Planning, Risk analysis, Safety requirements, Specification (approval), Stationary, Supplies, Surveillance (approval), Tank installations, Tanks (containers), Testing, Water demand, Water supply
117,29
Idioma Formato

Formato digital

Nota: Precios sin IVA ni gastos de envío