Saltar navegación principal
Normas DIN – AENOR
DIN EN ISO 11810:2014-06

DIN EN ISO 11810:2014-06

Lasers and laser-related equipment - Test method and classification for the laser resistance of surgical drapes and/or patient protective covers - Primary ignition, penetration, flame spread and secondary ignition (ISO/DIS 11810:2014); Version allemande prEN ISO 11810:2014 / Note: Date of issue 2014-05-09

Lasers et équipements associés aux lasers - Méthode d'essai et classification de la résistance au laser pour des draps chirurgicaux et/ou des couvertures de protection des patients - Inflammation primaire, pénétration et inflammation secondaire (ISO/DIS 11810:2014); Version allemande prEN ISO 11810:2014 / Attention: Date de parution 2014-05-09

Laser und Laseranlagen - Prüfverfahren und Einstufung zur Laserresistenz von Operationstüchern und/oder anderen Abdeckungen zum Schutz des Patienten - Primäre Entzündung, Laserdurchstrahlung und sekundäre Entzündung (ISO/DIS 11810:2014); Deutsche Fassung prEN ISO 11810:2014 / Achtung: Erscheinungsdatum 2014-05-09

Fecha Anulación:
2016-06 /Withdrawn
Equivalencias internacionales:

ISO/DIS 11810 (2014-04)

prEN ISO 11810 (2014-04)

Relación con otras normas DIN:

Reemplazada por: DIN EN ISO 11810:2016-06

Resumen:
This International Standard applies to disposable and reusable, as well as woven and non-woven materials used as surgical drapes and other patient protective covers which claim to be laser resistant. The purpose of this standard is to provide a standardized method for testing and classifying surgical drapes and other patient protective covers with respect to laser-induced hazards. It also covers the issue of laser-induced secondary ignition. An appropriate classification system is given. It is not the purpose of this standard to serve as a general fire safety specification, and as such, this standard does not cover other sources of ignition. All materials reflect portions of the beam and it is necessary for the user to decide whether specular reflectance may be a hazard. This measurement, however, is not covered in this standard. The results of this part of ISO 11810 are not to be applied to other wavelengths and temporal formats. The 20 W CO2 laser (continuous wave) has been selected as the laser to be used for ISO 11810. Users of products tested by this method are cautioned that the laser resistance of a surgical drape and/or patient protective cover will be wavelength sensitive and that a surgical drape and/or patient protective cover are better tested at the wavelength for which it is intended to be used. If tested using other wavelengths, the power settings and modes of delivery need to be explicitly stated.
Keywords:
Atmosphere, Chambers, Checking equipment, Classes, Classification, Cloth, Conditioning, Conditions, Cover cloths, Covers, Definitions, Disposable, Disposables, Energy, Environment, Equipment for single use, Fillers, Fine mechanics, Flammability, Ignitability, Ignition, Irradiation, Laser beams, Laser engineering, Laser equipment, Laser radiation, Laser-related equipment, Lasers, Layout, Medical devices, Medical equipment, Medical instruments, Medical technology, Non-woven fabrics, Optical equipment, Optical instruments, Optics, Oxygen, Patient protection, Patients, Penetrations, Performance, Plant, Protection, Protection against laser radiation, Protection coverings, Protective devices, Radiation, Radiation protection, Radiation resistance, Reflectance factor, Regulations, Resistance, Sampling methods, Specification (approval), Surgical drapes, Surgical instruments, Temperature, Test specimens, Testing, Use, Wavelengths, Woven fabrics
76,26