Saltar navegación principal
Normas DIN – AENOR
DIN EN 405:1993-02

DIN EN 405:1993-02

Respiratory protective devices; filtering half masks to protect against gases or gases and particles; requirements, testing, marking; german version EN 405:1992

Appareils de protection respiratoire; demi-masques filtrants contre les gaz ou contre les gaz et les particules; exigences, essais, marquage; version allemande EN 405:1992

Atemschutzgeräte; Filtrierende Halbmasken zum Schutz gegen Gase oder Gase und Partikeln; Anforderungen, Prüfung, Kennzeichnung; Deutsche Fassung EN 405:1992

Fecha Anulación:
2012-04 /Withdrawn
Equivalencias internacionales:

EN 405 (1992-11)

Relación con otras normas DIN:

Reemplazada por: DIN EN 405:2002-04

Resumen:
The document specifies performance requirements, test methods and marking requirements for valved filtering half masks incorporating either gas or combined filters as respiratory protective devices except for escape purposes.
Das Dokument legt Mindestanforderungen, Prüfmethoden und Anforderungen für Kennzeichnung für filtrierende Halbmasken mit Ventilen, die entweder ein Gasfilter oder ein Kombinationsfilter enthalten, als Atemschutzgeräte fest - außer für Fluchtzwecke.
Keywords:
Accident prevention, Breathing apparatus, Filters, Gases, Half masks, Marking, Masks, Particles, Protecting masks, Protection against poisonous gas, Protective clothing, Respirators, Specification (approval), Testing
77,76
Idioma Formato

Formato digital

Nota: Precios sin IVA ni gastos de envío

Añadir a la cesta