Saltar navegación principal
Normas DIN – AENOR
DIN ISO 16000-14:2007-10

DIN ISO 16000-14:2007-10

Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography/mass spectrometry (ISO/DIS 16000-14:2007)

Air intérieur - Partie 14: Détermination des polychlorobiphényles (PCB) de type dioxine et des polychlorodibenzo-p-dioxines (PCDD)/polychlorodibenzofuranes (PCDF) totaux (en phase gazeuse et en phase particulaire) - Extraction, nettoyage et analyse par chromatographie en phase gazeuse haute résolution/spectrométrie de masse (ISO/DIS 16000-14)

Innenraumluftverunreinigungen - Teil 14: Bestimmung der Summe gasförmiger und partikelgebundener polychlorierter dioxin-ähnlicher Biphenyle (PCB) und polychlorierter Dibenzo-p-dioxine/Dibenzofurane (PCDD/PCDF) - Extraktion, Reinigung und Analyse mit hochauflösender Gaschromatographie/Massenspektrometrie (ISO/DIS 16000-14:2007)

Fecha Anulación:
2012-03 /Withdrawn
Equivalencias internacionales:

ISO/DIS 16000-14 (2007-07)

Relación con otras normas DIN:

Reemplazada por: DIN ISO 16000-14:2012-03

Resumen:
This part of ISO 16000 describes the extraction, clean-up and analysis of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from indoor air. Sampling of PCBs, PCDDs/PCDFs is described in ISO 16000-13; it is part of the overall PCB/PCDD/PCDF measurement procedure. The sampling strategy to analyse PCBs, PCDDs/PCDFs and PAHs in indoor air is described in ISO 16000-12. After sampling on a filter and a back-up vapour trap (see DIN ISO 16000-13) the filter and the back-up vapour trap are extracted. The clean-up and the separation into a PCB and a PCDD/PCDF fraction are performed by column chromatography. For the analysis high-resolution gas chromatography combined with high-resolution mass spectrometry (HRGC/HRMS) is employed. Losses during extraction and clean-up are detected and compensated by using isotopically-labelled surrogates as internal extraction standards for quantification, together with recovery standards that are added just before the HRGC/HRMS analysis. The method provides accurate quantitative data for tetra- through deca-PCBs and tetra- through octa-PCDDs/PCDFs. It is capable of detecting 0,2 pg/m3 or lower concentrations of most PCBs and PCDFs/PCDDs with air sampling volumes up to 360 m3 or more in special cases. However, it may not be possible to detect all analytes at 0,2 pg/m3 or lower, especially at lower sampling volumes. Precision under normal conditions can be expected to be ± 25 % or better and uncertainty ± 50 % or better.
Keywords:
Air, Air pollution, Air quality, Analysis, Atmospheric pollutants, Chemical analysis and testing, Comparison measurement, Definitions, Determination, Determination of content, Determination procedures, Emission, Emission measurement, Gas chromatography, Impurities, Indoor climate, Indoors, Inner atmosphere, Mass spectrometry, Measurement, Measuring techniques, Metrology, Particulate matter measurement, PCB, PCDD, PCDF, Pollutant concentration, Pollutants, Pollution control, Pollution of the air, Polochlorinated dibenzo-p-dioxin, Polychlorinated, Polychlorinated biphenyls, Polychlorinated dibenzofuran, Prevention of pollution, Quality assurance, Sampling, Sampling methods, Testing, Volatile matter determination
112,15
Idioma Formato

Formato digital

Nota: Precios sin IVA ni gastos de envío