Saltar navegación principal
Normas BSI – AENOR
BS EN 61326-2-4:2013

BS EN 61326-2-4:2013

Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9

Fecha:
2013-02-28 /Revision Underway
Comité:
GEL/65/1
Equivalencias internacionales:

EN 61326-2-4:2013

IEC 61326-2-4:2012

Relación con otras normas BSI:

Reemplaza a: BS EN 61326-2-4:2006

Resumen:
IEC 61236-2-4:2012 specifies detailed test configurations, operational conditions and performance criteria for equipment for insulation monitoring according to IEC 61557-8 and insulation fault location according to IEC 61557-9. This applies to insulation monitoring devices and insulation fault location systems permanently or semi-permanently connected to the distribution system. This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision. It includes the following significant technical change: update of the document with respect to IEC 61326-1:2012.

This publication is to be read in conjunction with IEC 61326-1:2012.
Keywords:
Electromagnetic radiation, Electromagnetic fields, Rated voltage, Electromagnetic compatibility, Type testing, Electric control equipment, Electromagnetism, Electrical insulation, Performance, Laboratory equipment, Measuring instruments, Electrical equipment, Electrical measuring instruments, Electrical faults