Saltar navegación principal
Normas ASTM – AENOR
ASTM C1409-08

ASTM C1409-08

Standard Guide for Measuring and Estimating Quantities of Insulated Piping and Components

Fecha:
2012-10-22 /Historical
Superseeded by:
Significance and Use:

This guide establishes procedures to help parties involved in unit price piping insulation contracts reach agreement as to what components will be counted for pricing purposes.

Scope:

1.1 This guide defines the components of an insulated piping system to be measured or counted to determine quantities and pricing for unit price contracts or extra work.

1.2 Pricing may be done through unit pricing for each item by pipe size, type of insulation system, insulation thickness, double or multilayer insulation, type of weatherproofing or jacketing, and pressure rating (if necessary) or through component (fitting) factor or multipliers.

1.2.1 Component (fitting) factors or multipliers, which are multipliers times the straight length of piping as shown in Table 1, determine relative prices for each component not within the scope of this guide. These factors or multipliers are to be determined by the insulating contractor relative to the given situation and insulation system specification.

1.2.2 It is suggested that only one type of pricing be used on a project.

1.2.3 The values stated in inch-pound units are to be regarded as the standard.

Keywords:
extra work; factors; fittings; insulated pipe; measure quantities; piping components; unit prices; Double layer insulation; Fittings; Insulated pipe/equipment systems; Measurement processes/systems; Piping systems; Unit prices; Valves
51,1
Idioma Formato

Formato físico y digital

Nota: Precios sin IVA ni gastos de envío